CIP Pre-Validation

Dye Penetrant Testing

Hydro-Testing



CIP Pre-Validation:

Our custom designed and built CIP (Clean-In-Place) system includes a PLC for automatic control of flow, pressure and temperature. Timed bursts and other customer test requirements can be preprogrammed. A process recorder provides a printout of the parameters for each test.
Click here to go back to the top



Dye Penetrant Testing:

This test is used for location/identification of surface defects, detection of cracking in welded joints or of fatigue cracking in stressed materials.

The surface of the material being tested is coated with a penetrant which contains a dye. The penetrant will seep into any open areas on the material. After the excess penetrant is cleaned from the surface of the sample, a developer is applied. The developer lifts the penetrant out of the defect, and the dye stains the developer, creating an outline of the defect or crack.

Click here to go back to the top



Hydro-Testing:

Method of testing a vessel for leaks by filling with water and applying pressure.


Click here to go back to the top